The maintenance of Flood Control Water Pump is an important measure to ensure its normal operation and effective drainage at critical moments. The following is a detailed summary of the maintenance and upkeep of flood control water pumps:
1、 Flood control water pump daily inspection and maintenance
Maintain cleanliness: Regularly clean the surface of the water pump body to ensure that there is no dust, debris, or aquatic organisms adhering to it. At the same time, clean up debris from oil pipe joints, valves, and oil tanks.
Check the oil level and quality: Ensure that the oil level of the water pump is moderate and the oil quality is clean. For water pumps that use lubricating oil, regular inspection and replacement of lubricating oil should be carried out; For water pumps that use lubricating grease, the grease should be regularly replenished or replaced.
Fasteners for flood control water pump: Check whether the bolts, nuts, and other fasteners at all parts of the water pump are loose or detached. If they are loose, they should be tightened in a timely manner.
2、 Monitoring and maintenance of flood control water pump during operation
Monitor operating sound and vibration: During the operation of the water pump, close attention should be paid to its operating sound and vibration. If abnormal noise or excessive vibration is found, the machine should be stopped immediately to check the cause.
Check instrument readings: Regularly check whether the readings of pressure gauges, vacuum gauges, and other instruments on the water pump are normal. If abnormal readings are found, the cause should be promptly investigated and dealt with.
Pay attention to cooling and lubrication: For water pump components that require cooling and lubrication, ensure that the cooling water flow is sufficient, the temperature is appropriate, and the lubricating oil or grease is sufficient and of good quality.
3、 Flood control water pump undergoes regular comprehensive maintenance
Disassembly inspection and cleaning: Regularly disassemble the water pump for comprehensive inspection, clean internal parts and piping systems, and remove dirt and debris.
Replace vulnerable parts: Regularly replace vulnerable parts such as seals, bearings, etc. according to the usage of the water pump and the requirements of the maintenance manual.
Anti corrosion treatment: For water pumps that have been out of use for a long time or in humid environments, anti-corrosion treatment should be carried out to prevent rust and corrosion.
4、 Maintenance of Flood Control Water Pump during Long Term Discontinuation
Drain the liquid: For water pumps that have been out of use for a long time, the liquid inside the pump should be drained to prevent rusting and corrosion.Disassemble and store: Disassemble the water pump for cleaning and rust prevention treatment, then reinstall it and store it properly. When storing, the rotating parts and joints should be coated with grease to prevent rusting.