When storing Huaquan generator set in winter, the following key aspects should be noted to ensure the performance of the units and extend their service life:
1、 Huaquan generator set lubrication system and cooling system
Huaquan generator set oil and filter: Ensure the normal operation of the lubrication system, regularly replace the oil, let the new oil reach the parts that need lubrication, and prevent parts wear and failure. Check the condition of the oil filter and replace it with a new one if it is damaged.
Antifreeze: Check the antifreeze level in the water tank to ensure that the antifreeze is sufficient. If it does not meet the standard, it should be added or replaced in a timely manner.
For the unit radiator, sufficient antifreeze should be added to prevent the engine from rusting or freezing in cold seasons.
2、 Fuel system of Huaquan generator set
Diesel quality: Check the quality of diesel in the unit. Diesel stored for a long time may deteriorate, and if necessary, replace it with new diesel.
Fuel filter: Check the condition of the fuel filter, replace the filter if necessary, and ensure that the fuel passage is unobstructed.
Fuel system cleanliness: Keep the fuel system clean to avoid impurities from entering the fuel, which may affect the normal operation of the engine.
3、 Battery and Electrical System
Battery status: During storage, the battery may naturally discharge, so the battery's charge status should be checked before storage and charged to an appropriate level.
Clean the battery terminals and ensure that the battery cables are securely connected and can store electricity normally.
Electrical system inspection: Check the electrical system of the generator set, including wire connections, instruments and indicator lights on the control panel, etc., to ensure that there is no damage or malfunction.
4、 Huaquan generator set body and external environment
Body cleaning: Clean the dust, oil stains and other debris on the surface of the Huaquan generator set to keep the unit clean.
Storage environment: The generator set should be stored in a well ventilated, dry, and clean place to avoid moisture and corrosion.
If the unit is placed outdoors, snow prevention measures need to be taken to prevent snow accumulation from causing malfunctions or hindering normal operation.
Insulation and heating: Equip the generator set with insulation sleeves and curtains to prevent excessive cooling of the diesel engine.
During the long-term low temperature period (temperature below 4 ℃), the cooling water inside the Huaquan generator set should be drained to prevent damage to the radiator of the cooling water tank caused by the increase in cooling water volume.
5、 Huaquan generator set start-up and testing
Preheating: Before starting the Huaquan generator set, a preheating operation should be carried out to ensure that the diesel is fully atomized, improve the engine's starting performance and operational stability.
System testing: After being stored for a period of time, the generator set should undergo system testing, including checking whether the instruments and indicator lights on the control panel can display normally, and whether the unit can start and operate normally.
Load operation: Perform appropriate load operation to ensure that the generator set can operate normally and provide stable power.
In summary, when storing Huaquan generator sets in winter, special attention should be paid to the maintenance of lubrication and cooling systems, cleaning and inspection of fuel systems, monitoring of battery and electrical systems, protection of the body and external environment, and preparation for start-up and testing. These measures help ensure that the generator set maintains good performance during winter storage, providing reliable guarantees for subsequent use.